AudioChainsDB
Neumann

TLM 107

microphone

$1,699

Gebrauchtmarkt: $1,325*

Datenblatt des Herstellers

Technische Daten

5 von 7 Werten mit vermerkter Quelle
Connectors
XLR 3-Pin Male·
Has Built In ADC
no·
Transducer Type
Condenser True
Sensitivity dBV
-39.2
Output Impedance ohms
50
Phantom Power Required
yes
Connection Architecture
XLR-Only

Kommentar des Toningenieurs

Tonal Profile

Large-diaphragm five-pattern condenser with a joystick for pattern, pad and high-pass; transformerless output, 10 dB-A self-noise.

Gain Staging Advice

11 mV/Pa - exactly the figure Neumann prints for the far cheaper TLM 102, and the same -39.2 dBV/Pa follows from it. What the extra money buys is not level: it is 2 dB less self-noise, five patterns, and a 141 dB max SPL that reaches 153 dB with the pre-attenuation. For the gain calculation the two microphones are interchangeable.

Was im Datenblatt tatsächlich steht

Wörtlich von der Herstellerseite zitiert, mit dem Datum der Prüfung. Wir behaupten das Gedruckte, nicht die Absicht dahinter.

Messbedingungen
«Directional Pattern: Omni, wide angle cardioid, cardioid, hypercardioid, figure-8. Sensitivity at 1 kHz into 1 kohm: 11 mV/Pa»

Für fünf umschaltbare Richtcharakteristiken wird ein einziger Empfindlichkeitswert angegeben, ohne zu nennen, in welcher gemessen wurde. Die Empfindlichkeit ist in Kugel und Acht nicht gleich: Neumanns eigene U-87-Ai-Seite nennt 20/28/22 mV/Pa für Kugel, Niere und Acht, also 2,9 dB Spanne bei einer Kapsel. Der einzelne Wert ist somit entweder der Nierenwert oder ein Typwert; das Datenblatt unterscheidet das nicht. Dieselbe Seite druckt einen Ersatzgeräuschpegel, 10 dB-A, für alle fünf Charakteristiken, die U-87-Ai-Seite dagegen drei. Praktisch: Verstärkung für die tatsächlich genutzte Charakteristik planen, einige dB Spielraum einrechnen und 11 mV/Pa als Nierenwert behandeln.

geprüft am 5.8.2026

* Geschätzt über das Abschreibungsmodell (~78% Restwert). · geprüft am 5.8.2026