Technische Daten

2 von 8 Werten mit vermerkter Quelle
Connectors
XLR 3-Pin Male·
Has Built In ADC
no·
Transducer Type
Dynamic Moving Coil·
Sensitivity dBV
-74
Output Impedance ohms
350·
Phantom Power Required
no·
Connection Architecture
XLR-Only·
Updated At
2026-08-05T23:39:34.353Z·

Kommentar des Toningenieurs

Tonal Profile

A kick-drum cardioid with a shock-mounted capsule and a hum-bucking coil, deliberately deaf in the midrange. Sennheiser publishes two sensitivities for it - 0.6 mV/Pa at 60 Hz and 0.2 mV/Pa at 1 kHz - which is the response curve stated as numbers: a 9.5 dB difference between where the drum lives and where the catalogue measures.

Gain Staging Advice

-74 dBV/Pa at 1 kHz is the catalogue-comparable figure and it makes the e 902 look like it needs 70 dB of gain. It does not: on a kick the energy is at 60 Hz, where the same microphone is 9.5 dB louder, and the source is 130 dB SPL. Do not size the preamp from the 1 kHz number, and do not compare it with a vocal dynamic measured at 1 kHz - they are not describing the same job.

Was im Datenblatt tatsächlich steht

Wörtlich von der Herstellerseite zitiert, mit dem Datum der Prüfung. Wir behaupten das Gedruckte, nicht die Absicht dahinter.

Herstellerdokumente widersprechen sich
«Frequency response 20 - 18,000 Hz»

The specification table on page one says 20 - 18,000 Hz. The Architect's Specification paragraph printed beside it, on the same page of the same PDF, says 'The frequency response shall be 40 Hz - 16,000 Hz'. The two ends differ by an octave at the bottom and two kilohertz at the top, on a microphone bought specifically for its low-frequency behaviour. The paragraph and the table agree on every other quantity, sensitivity included.

geprüft am 6.8.2026

* Geschätzt über das Abschreibungsmodell (~79% Restwert). · geprüft am 6.8.2026